The difference

From dead zones to code-compliant coverage FAIL· 33% general coverage

A failing benchmark test is the legal trigger for an ERCES. Toggle the building below to see how a roof donor antenna, a COMBA bi-directional amplifier, and a coax riser carry public-safety signal to every floor, the outcome we engineer and then prove with an on-site grid test.

  • 1.35 miDonor link
  • -61 dBmIncoming
  • 27 dBmClass A BDA
  • 33.9 hrLiFePO4 BBU
  • 54Dome antennas
  • 81,706Sq ft covered
Public-safety radio coverage by floor, before and after the ERCES install. Code minimum is 95% of general areas and 99% of critical areas at or above -95 dBm, per IFC 510 / NFPA 1225.
FloorRiser gainBefore (dBm)Before coverageAfter (dBm)After coverage
F710 dB → +9 dBm-1224%-7895%
F68 dB → +10 dBm-1188%-7496%
F58 dB → +10 dBm-11016%-7097%
F48 dB → +10 dBm-10427%-6799%
F35 dB → +13 dBm-9641%-6398%
F25 dB → +13 dBm-8858%-6099%
G5 dB → +18 dBm-7278%-5899%
Whole building33% · FAIL98% general, 99% critical · PASS

Code minimum · ≥95% general / ≥99% critical @ ≥ -95 dBm · IFC 510 / NFPA 1225Illustrative, modeled on a real 7-floor project.